Low Noise Commercial Cabinet Centrifugal Extractor Fan VT-TW - China Suppliers & Factory for Restaurants and Hotels
Forward Curved Centrifugal Impeller
- Configure Forward Inclined Multiple Blades Centrifugal Impeller | Hub Parallel to the Edge & Outlet Angle Greater Than 90°
- Small Shafts & Bearings Achieve Wider Operating Range | Suitable for Place with High Pressure & Small Air Volume | Air Cooling System ( HVAC ) / Kitchen Fume Purification Equipment / Air Filter
Exhaust 1967m³/h to 108252m³/h Air
- Configure 550W to 30kW Strong Power Motor with Belt-drive Method | Quickly Rotating Impeller to Generate Centrifugal Force
- Help You Discharge or Input 1967m³ to 61124m³ Air / Oil Mist / Dust Per Hour | The Motor + Impeller + Belt has been Balanced and Corrected for Dynamic Pressure and Static Pressure | Generate Low Noise ( <88db)
Stainless Steel Structure
- Adopts Stainless Steel Casing and Structure | Detachable Design and Easy to Install / Maintain / Clean | Resistance High Air Temperature / Corrosion | Meet Hygienic Standard
- Stainless Steel Casing Provides A Safe Environment for the Impeller / Motor / other Critical Component | Help You Reduce Repair or Maintenance Cost
Product Video
Product Parameters
| Model | Size (mm) | Inlet size (mm) | Outlet size (mm) | Air flow (m³/h) | Rotate Speed (r/min) | Max pressure (pa) | Static pressure (pa) | Power (KW) | Noise (db) | Weight (kg) |
|---|---|---|---|---|---|---|---|---|---|---|
| VT-TW-9"-A/B | L710*W510*H490 | W530*H390 | L310*H255 | 1967 to 3005 | 1100 | 220 to 187 | 190 to 107 | 0.55 | ≤60 | 90 |
| VT-TW-10"A/B | L760*W560*H510 | W580*H410 | L340*H280 | 2328 to 3927 | 970 | 233 to 195 | 206 to 115 | 0.75 | ≤61 | 105 |
| VT-TW-12"A/B | L860*W620*H590 | W660*H490 | L390*H330 | 2875 to 6067 | 950 | 305 to 287 | 283 to 192 | 1.1 | ≤63 | 113 |
| VT-TW-15"A/B | L920*W760*H720 | W720*H620 | L445*H405 | 4344 to 8060 | 900 | 407 to 419 | 382 to 334 | 1.5 | ≤65 | 125 |
| VT-TW-18"A/B | L1070*W860*H840 | W830*H740 | L540*H480 | 7975 to 14413 | 760 | 384 to 291 | 342 to 151 | 3 | ≤68 | 187 |
| VT-TW-20"A/B | L1220*W970*H940 | W980*H840 | L615*H545 | 12065 to 18256 | 680 | 406 to 373 | 352 to 248 | 4 | ≤67 | 223 |
| VT-TW-22"A/B | L1320*W1020*H1000 | W1060*H900 | L675*H610 | 15150 to 23888 | 650 | 484 to 349 | 424 to 199 | 5.5 | ≤70 | 255 |
| VT-TW-25"A/B | L1470*W1070*H1100 | W1210*H1000 | L765*H690 | 19890 to 31754 | 660 | 544 to 450 | 481 to 289 | 7.5 | ≤73 | 299 |
| VT-TW-27.5"A/B | L1630*W1270*H1270 | W1350*H1170 | L850*H740 | 21805 to 38171 | 620 | 637 to 651 | 585 to 488 | 11 | ≤78 | 458 |
| VT-TW-30"A/B | L1780*W1370*H1370 | W1500*H1270 | L915*H825 | 28145 to 48540 | 540 | 589 to 517 | 525 to 318 | 15 | ≤80 | 561 |
| VT-TW-36"A/B | L2000*W1370*H1370 | W1720*H1270 | L1070*H825 | 45982 to 61882 | 550 | 551 to 495 | 451 to 302 | 18.5 | ≤84 | 618 |
| VT-TW-40"A/B | L2200*W1700*H1720 | W1900*H1620 | L1200*H1100 | 44000 to 88195 | 440 | 675 to 588 | 644 to 461 | 30 | ≤86 | 746 |
Product Application
This VT-TW Low Noise Commercial Cabinet Centrifugal Extractor Fan specially designed for ventilation in cinemas, hotels and canteens.
Chemical factory
Cinema
Hotel
Canteen
Get in Touch with Ventpu Manufacturer
Related Products
Frequently Asked Questions
What are the main applications of the VT-TW commercial cabinet centrifugal extractor fan?
This extractor fan is specifically designed for ventilation systems in cinemas, hotels, canteens, chemical factories, HVAC air cooling systems, kitchen fume purification equipment, and air filters.
What is the range of air flow that these centrifugal fans can handle?
The VT-TW series can discharge or input air flow ranging from 1,967 m³/h to 108,252 m³/h, depending on the model and motor power configuration.
What are the benefits of the stainless steel structure of the fan?
The stainless steel casing and structure offer high-temperature and corrosion resistance, meet hygienic standards, protect critical internal components, and feature a detachable design that makes installation, cleaning, and maintenance easy.
How does the forward curved centrifugal impeller configuration work?
It features a forward-inclined multiple-blade centrifugal impeller with the hub parallel to the edge and an outlet angle greater than 90°. Utilizing small shafts and bearings, it achieves a wider operating range ideal for high-pressure, small air volume requirements.
How is low noise operation achieved in these fans?
The motor, impeller, and belt drive system are balanced and corrected for both dynamic and static pressure. This ensures smooth operation and limits noise levels to below 88dB (with many smaller models operating under 60-70dB).
What motor power options are available for the VT-TW fan series?
The VT-TW series supports strong power motors ranging from 550W (0.55 kW) up to 30kW, driven by a reliable belt-drive system to generate optimal centrifugal force.