Leave Your Message

Commercial Backward Curved Centrifugal Blower VT-4-72-A from China Suppliers - Factory Direct for Oil Fume Control

,

The Commercial Backward-Curved Centrifugal Blower is an essential solution for industries seeking high efficiency in oil fume adsorption. Designed with a high temperature-resistant impeller, this blower is ideal for delivering purified oil fume output or fresh air input, making it perfect for restaurant kitchens and commercial premises. As a leading manufacturer and supplier in China, our factory ensures top-quality performance and durability.

,

 

,

Model No: VT-4-72-A

,

Certification: ISO, CEP

,

Services: Customized OEM and ODM solutions available

,

emailphonewhatsappfacebooklinkedintwitteryoutube

,

Backward Curved Impeller
01

Backward Curved Impeller

  • Configure Backward Inclined Centrifugal Impeller ( Facing Away from Air Inlet ) | Suitable for Occasions with Large amount of Airflow & Low Static Pressure
  • When Air Through the Centrifugal Fan Continues to Increase | Decrease Component Force Loss | Help You Improves Exhaust Efficiency
  • Configure Gentle Curved Blade Channel for Backward Inclined Centrifugal Impeller | Low Noise ( <71db) During Operation
Stainless Steel Structure
02

Stainless Steel Structure

  • Stainless Steel Shell & Structure | Resistance High Air Temperature + Stains Corrosion | Work Stably Under High-temperature Conditions | Industrial Drying / Heat Treatment | Stainless Steel Volute Reduces Noise
Strong Power Motor
03

Strong Power Motor

  • Configure Strong Power Motor | Belt-drive Method | High Speed Rotating Impeller Generates Centrifugal Force Absorb & Discharge Air | Pushing Air in the Ventilation Duct / Indoor / Exhaust System
  • Motor Speed Configuration Not Overload | the Impeller & Belt Undergone Strict Dynamic & Static Balance Correction | High Performance Spring Shock | Prevent High Noise During Operation
Exhaust Volume
04

2006m³/h to 21206m³/h Exhaust Volume

  • Help You Extract 2006m³ to 21206m³ Gaseous Pollutant Per Hour | Increase the Speed of Air Flow & More Kinetic Energy | Create Cool / Clean Environment for You
  • Suitable for Large Factory Purification Equipment, Civil Buildings, Large Squares, Generators, Air Treatment Equipment, and Hot Air Circulation Systems.

Product Video

Product Parameters

Model Size (mm) Air Flow (m³/h) Air Inlet Size (mm) Air Outlet Size (mm) Rotary Speed (r/min) Max Pressure (pa) Power / Voltage Weight (kg)
VT-4-72-4A L735*W800*H709 4012 to 7419 Φ400 L400*W360 2900 2014 to 1320 5.5KW / 380V 125
2006 to 3709 1450 501 to 329 1.1KW / 380V 82
VT-4-72-4.5A L800*W895*H790 2856 to 5281 Φ450 L440*W395 1450 634 to 416 1.1KW / 380V 96
5712 to 10562 2900 2554 to 1673 7.5KW / 380V 145
VT-4-72-5A L960*W990*H870 3864 to 7728 Φ500 L480*W430 1450 790 to 502 2.2KW / 380V 132
7728 to 15455 2900 3187 to 2019 15KW / 380V 230
VT-4-72-5.6A L1160*W1105*H987 5429 to 10857 Φ560 L528*W472 1450 999 to 633 3KW / 380V 164
10858 to 21714 2900 3996 to 2533 22KW / 380V 294
VT-4-72-6A L852*W1180*H1056 4420 to 8841 Φ630 L620*W500 960 498 to 317 1.5KW / 380V 165
6677 to 13353 1450 1139 to 724 4KW / 380V 177
VT-4-72-7A L1125*W1380*H1233 10603 to 21206 Φ710 L660*W590 1450 1548 to 984 11KW / 380V 300

Product Application

This Commercial Backward Curved Centrifugal Blower was purchased by many canteens, power plants, warehouses, and large plazas for its exhaust speed and low energy consumption.
Canteen

Canteen

Factory

Factory

Power plant

Power plant

Warehouse

Warehouse

Get in Touch with Ventto Manufacturer

Related Products

Frequently Asked Questions (FAQ)

What are the main benefits of a backward curved impeller?
Backward curved impellers are highly suitable for operations requiring a large amount of airflow with low static pressure. They minimize component force loss to improve overall exhaust efficiency, while maintaining a low operational noise level of less than 71dB.
Is this commercial blower suitable for high-temperature environments?
Yes. Designed with a robust stainless steel shell and structure, it resists high air temperatures and stain corrosion. This makes it ideal for stable performance under high-temperature conditions, such as industrial drying and heat treatment.
What is the exhaust volume capacity of the Ventto centrifugal blower?
The blower models offer a wide exhaust volume capacity ranging from 2006m³/h to 21206m³/h, helping efficiently extract gaseous pollutants and increase indoor air circulation.
How does the motor drive system prevent excessive noise and vibration?
The blower utilizes a belt-drive configuration. Both the impeller and belt undergo strict dynamic and static balance corrections, paired with high-performance spring shock absorbers, to prevent high operational noise and vibration.
What applications is this centrifugal blower designed for?
It is widely used in commercial canteens, factories, power plants, warehouses, large plazas, civil buildings, generator rooms, air treatment equipment, and hot air circulation systems.
What power and voltage configurations are available?
The blower models support power configurations from 1.1KW up to 22KW, operating on a standard 380V voltage system to deliver strong and reliable industrial ventilation.