China Suppliers VT-HQ Double Inlet Commercial Backward Curved Centrifugal Fan Factory - 7,848 to 10,618 m³/h
01
Backward Curved Centrifugal Impeller
- Configure Backward Curved Centrifugal Impeller (Less Than 90° to the Air Outlet) | High Exhaust Efficiency / Low Noise
- Help You Discharge 2689m³/h to 84000m³ Air Per Hour | Suitable for Ventilation / Kitchen Fume / Dust Exhaust System with High Static Pressure & Long Ventilation Ducts
02
Strong Power Motor
- Configure Strong Power Motor | Belt-drive Method | High Speed Rotating Impeller Generates Centrifugal Force Absorb & Discharge Air | Pushing Air in the Ventilation Duct / Indoor / Exhaust System
- Motor Speed Configuration Not Overload | the Impeller & Belt Undergone Strict Dynamic & Static Balance Correction | High Performance Spring Shock | Prevent High Noise During Operation
03
Stainless Steel Structure
It adopts a stainless steel structure and cabinet to operate stably in high-temperature, humid, and cold working environments.
The whole machine adopts a detachable structure, and the power part of the fan is separated from the casing, making it easy to clean/maintain and inspect.
Product Video
Product Parameters
| Model | Size (mm) | Air Inlet Size (mm) | Air Outlet Size (mm) | Air Flow (m³/h) | Rotate speed (r/min) | Max Pressure (pa) | Static Pressure (pa) | Power (kW) | Noise (db) | Weight (kg) |
|---|---|---|---|---|---|---|---|---|---|---|
| VT-HQ-400(15")-A/B | L950*W820*H820 | W750*H720 | L505*H505 | 7848 to 10618 | 1700 | 814 to 348 | 809 to 288 | 2.2 | ≤71 | 197 |
| VT-HQ-450(18")-A/B | L1100*W860*H880 | W900*H780 | L560*H560 | 4500 to 12329 | 1600 | 921 to 431 | 911 to 360 | 3 | ≤73 | 218 |
| VT-HQ-500(20")-A/B | L1260*W1010*H960 | W1060*H860 | L640*H640 | 4612 to 15565 | 1400 | 899 to 412 | 893 to 346 | 4 | ≤75 | 298 |
| VT-HQ-560(22")-A/B | L1360*W1100*H1100 | W1160*H1000 | L700*H700 | 5812 to 19577 | 1300 | 965 to 465 | 959 to 391 | 5.5 | ≤75 | 323 |
| VT-HQ-630(25")-A/B | L1520*W1150*H1230 | W1320*H1130 | L800*H800 | 8517 to 27429 | 1200 | 1037 to 382 | 1029 to 298 | 7.5 | ≤76 | 365 |
| VT-HQ-710(28")-A/B | L1670*W1310*H1350 | W1470*H1250 | L900*H900 | 9731 to 34411 | 1100 | 1074 to 476 | 1067 to 392 | 11 | ≤76 | 528 |
| VT-HQ-800(30")-A/B | L1800*W1400*H1520 | W1500*H1420 | L1000*H1000 | 12083 to 45000 | 1000 | 1170 to 438 | 1163 to 345 | 15 | ≤76 | 721 |
| VT-HQ-900(36")-A/B | L1900*W1700*H1700 | W1600*H1600 | L1130*H1130 | 18474 to 55898 | 900 | 1141 to 472 | 1131 to 384 | 18.5 | ≤76 | 865 |
| VT-HQ-1000(40")-A/B | L2100*W1900*H1900 | W1800*H1800 | L1260*H1260 | 24800 to 64000 | 800 | 1155 to 503 | 1144 to 428 | 22 | ≤75 | 913 |
Application
This Commercial Double Air Inlet Centrifugal Fan is suitable for ventilation in chemical factories, construction, shopping malls, or kitchen fume exhaust systems.
Chemical factory
Construction Site
shopping mall
Warehouse
Get in Touch with Ventto Manufacturer
Related Products
Industrial Kitchen Backward Curved Air Blower
Single Inlet Forward Curved Commercial Centrifugal Blower Fan
Backward Curved Industrial Cabinet Centrifugal Fan
Low Noise Commercial Cabinet Centrifugal Extractor Fan
Professional Oil Fume Purified Centrifugal Fan
High Exhaust Speed Suspension Mute Centrifugal Fan
Frequently Asked Questions
What are the primary applications for the VT-HQ series centrifugal fans?
The VT-HQ series centrifugal fans are highly suitable for high static pressure ventilation systems, commercial kitchen fume exhaust, dust collection setups, chemical plants, shopping malls, construction sites, and warehouses with long ventilation duct networks.
What are the advantages of using a backward curved centrifugal impeller?
A backward curved centrifugal impeller (configured at less than 90° to the air outlet) offers superior exhaust efficiency and operates with lower noise levels. It is designed to handle high static pressure systems and move air efficiently through long ducts without overloading the motor.
How does the belt-drive motor configuration prevent operational noise?
The belt-drive method ensures smooth power transmission. Both the impeller and belt undergo rigorous dynamic and static balance corrections. Combined with high-performance spring shock absorbers, it prevents excessive vibration and keeps noise levels low during operation.
Is the stainless steel structure suitable for harsh environments?
Yes, the stainless steel structure and cabinet are specifically engineered to remain stable and resist corrosion in high-temperature, humid, and cold working environments.
How easy is it to clean and maintain the centrifugal fan?
The entire machine features a detachable structure where the power section of the fan is separated from the casing. This user-friendly design makes routine inspection, maintenance, and cleaning incredibly straightforward.
What is the range of air flow capacity available in the VT-HQ series?
The air flow capacity ranges from 2,689 m³/h to 84,000 m³/h depending on the selected model size (from the VT-HQ-400 up to the large-scale VT-HQ-1000 model).