The VT-HQ Double Inlet Backward Curved Centrifugal Fan is an essential solution for effective ventilation in restaurants, commercial establishments, and chemical industries. With a robust exhaust air volume ranging from 7,848 m³/h to 10,618 m³/h, this fan ensures optimal air circulation and pollution control.

,

Model: VT-HQ

,

Certificate: ISO / CEP

,

Service: Customized OEM / ODM

,

As a leading manufacturer in China, we take pride in being a reliable supplier of high-quality ventilation equipment. Our factory employs advanced technology to ensure that our products meet the highest industrial standards.

,

For inquiries, feel free to reach out:

,

emailphonewhatsappfacebooklinkedintwitteryoutube

,

Backward Curved Centrifugal Impeller

Backward Curved Centrifugal Impeller

  • Configure Backward Curved Centrifugal Impeller (Less Than 90° to the Air Outlet) | High Exhaust Efficiency / Low Noise
  • Help You Discharge 2689m³/h to 84000m³ Air Per Hour | Suitable for Ventilation / Kitchen Fume / Dust Exhaust System with High Static Pressure & Long Ventilation Ducts
Strong Power Motor

Strong Power Motor

  • Configure Strong Power Motor | Belt-drive Method | High Speed Rotating Impeller Generates Centrifugal Force Absorb & Discharge Air | Pushing Air in the Ventilation Duct / Indoor / Exhaust System
  • Motor Speed Configuration Not Overload | the Impeller & Belt Undergone Strict Dynamic & Static Balance Correction | High Performance Spring Shock | Prevent High Noise During Operation
Stainless Steel Structure

Stainless Steel Structure

  • It adopts a stainless steel structure and cabinet to operate stably in high-temperature, humid, and cold working environments.
  • The whole machine adopts a detachable structure, and the power part of the fan is separated from the casing, making it easy to clean/maintain and inspect.

Product Video

Product Parameters

Model Size(mm) Air Inlet Size(mm) Air Outlet Size(mm) Air Flow(m³/h) Rotate speed(r/min) Max Pressure(pa) Static Pressure(pa) Power (kW) Noise (db) Weight (kg)
VT-HQ-400(15")-A/B L950*W820*H820 W750*H720 L505*H505 7848 to 10618 1700 814 to 348 809 to 288 2.2 ≤71 197
VT-HQ-450(18")-A/B L1100*W860*H880 W900*H780 L560*H560 4500 to 12329 1600 921 to 431 911 to 360 3 ≤73 218
VT-HQ-500(20")-A/B L1260*W1010*H960 W1060*H860 L640*H640 4612 to 15565 1400 899 to 412 893 to 346 4 ≤75 298
VT-HQ-560(22")-A/B L1360*W1100*H1100 W1160*H1000 L700*H700 5812 to 19577 1300 965 to 465 959 to 391 5.5 ≤75 323
VT-HQ-630(25")-A/B L1520*W1150*H1230 W1320*H1130 L800*H800 8517 to 27429 1200 1037 to 382 1029 to 298 7.5 ≤76 365
VT-HQ-710(28")-A/B L1670*W1310*H1350 W1470*H1250 L900*H900 9731 to 34411 1100 1074 to 476 1067 to 392 11 ≤76 528
VT-HQ-800(30")-A/B L1800*W1400*H1520 W1500*H1420 L1000*H1000 12083 to 45000 1000 1170 to 438 1163 to 345 15 ≤76 721
VT-HQ-900(36")-A/B L1900*W1700*H1700 W1600*H1600 L1130*H1130 18474 to 55898 900 1141 to 472 1131 to 384 18.5 ≤76 865
VT-HQ-1000(40")-A/B L2100*W1900*H1900 W1800*H1800 L1260*H1260 24800 to 64000 800 1155 to 503 1144 to 428 22 ≤75 913

Application

This Commercial Double Air Inlet Centrifugal Fan is suitable for ventilation in chemical factories, construction, shopping malls, or kitchen fume exhaust systems.

Chemical factory

Chemical factory

Construction Site

Construction Site

shopping mall

shopping mall

Warehouse

Warehouse

Get in Touch with Ventto Manufacturer

Frequently Asked Questions

What are the benefits of the Backward Curved Centrifugal Impeller design?

The backward curved centrifugal impeller is configured at less than 90° to the air outlet. This configuration provides high exhaust efficiency and ensures low noise levels during operation, making it ideal for high-capacity ventilation.

What range of air flow can this centrifugal fan system handle?

This system can discharge from 2,689 m³/h to 84,000 m³ of air per hour. It is highly suitable for ventilation, kitchen fume extraction, and dust exhaust systems with high static pressure and long ventilation ducts.

How does the strong power motor reduce noise and vibration?

The motor utilizes a belt-drive system. The impeller and belt undergo strict dynamic and static balance corrections. This is paired with high-performance spring shock absorption to prevent high noise and vibration during rotation.

Is the structure durable for extreme working environments?

Yes, it adopts a heavy-duty stainless steel structure and cabinet. This design ensures stable operation in high-temperature, highly humid, and cold working environments.

How easy is it to maintain and clean the fan?

The entire machine features a modular, detachable structure. The power portion of the fan is separated from the main casing, allowing for easy access during inspection, cleaning, and routine maintenance.

What are the primary applications of this centrifugal fan?

This commercial double air inlet centrifugal fan is ideal for ventilation and fume extraction in chemical factories, construction sites, shopping malls, warehouses, and commercial kitchen exhaust systems.

LF-HQ-400 The Backward Impeller of Commercial Kitchen Centrifugal Exhaust Fan (1)sl0

Backward Curved Centrifugal Impeller

  • Configure Backward Curved Centrifugal Impeller(Less Than 90° to the Air Outlet) | High Exhaust Efficiency / Low Noise
  • Help You Discharge 2689m³/h to 84000m³ Air Per Hour | Suitable for Ventilation / Kitchen Fume / Dust Exhaust System with High Static Pressure & Long Ventilation Ducts
LF-HQ-400 The Backward Impeller of Commercial Kitchen Centrifugal Exhaust Fan (1)4qv

Strong Power Motor

  • Configure Strong Power Motor | Belt-drive Method | High Speed Rotating Impeller Generates Centrifugal Force Absorb & Discharge Air | Pushing Air in the Ventilation Duct / Indoor / Exhaust System
  • Motor Speed Configuration Not Overload | the Impeller & Belt Undergone Strict Dynamic & Static Balance Correction | High Performance Spring Shock | Prevent High Noise During Operation
LF-HQ-400 The Backward Impeller of Commercial Kitchen Centrifugal Exhaust Fan (2)p7l

Stainless Steel Structure

It adopts a stainless steel structure and cabinet to operate stably in high-temperature, humid, and cold working environments.
The whole machine adopts a detachable structure, and the power part of the fan is separated from the casing, making it easy to clean/maintain and inspect.
Product Video
Product Parameters
Model Size(mm) Air Inlet Size(mm) Air Outlet Size(mm) Air Flow(m³/h) Rotate speed(r/min) Max Pressure(pa) Static Pressure(pa) Power (kW) Noise (db) Weight (kg)
VT-HQ-400(15")-A/B L950*W820*H820 W750*H720 L505*H505 7848 to 10618 1700 814 to 348 809 to 288 2.2 ≤71 197
VT-HQ-450(18")-A/B L1100*W860*H880 W900*H780 L560*H560 4500 to 12329 1600 921 to 431 911 to 360 3 ≤73 218
VT-HQ-500(20")-A/B L1260*W1010*H960 W1060*H860 L640*H640 4612 to 15565 1400 899 to 412 893 to 346 4 ≤75 298
VT-HQ-560(22")-A/B L1360*W1100*H1100 W1160*H1000 L700*H700 5812 to 19577 1300 965 to 465 959 to 391 5.5 ≤75 323
VT-HQ-630(25")-A/B L1520*W1150*H1230 W1320*H1130 L800*H800 8517 to 27429 1200 1037 to 382 1029 to 298 7.5 ≤76 365
VT-HQ-710(28")-A/B L1670*W1310*H1350 W1470*H1250 L900*H900 9731 to 34411 1100 1074 to 476 1067 to 392 11 ≤76 528
VT-HQ-800(30")-A/B L1800*W1400*H1520 W1500*H1420 L1000*H1000 12083 to 45000 1000 1170 to 438 1163 to 345 15 ≤76 721
VT-HQ-900(36")-A/B L1900*W1700*H1700 W1600*H1600 L1130*H1130 18474 to 55898 900 1141 to 472 1131 to 384 18.5 ≤76 865
VT-HQ-1000(40")-A/B L2100*W1900*H1900 W1800*H1800 L1260*H1260 24800 to 64000 800 1155 to 503 1144 to 428 22 ≤75 913
Application
This Commercial Double Air Inlet Centrifugal Fan is suitable for ventilation in chemical factories, construction, shopping malls, or kitchen fume exhaust systems.
Get in Touch with Ventto Manufacturer
Frequently Asked Questions
Q1: What are the benefits of a backward curved centrifugal impeller?
A: Backward curved impellers are highly efficient and operate stably under high static pressure. Their unique design prevents overloading of the motor, making them perfect for long ventilation ducts and high-resistance exhaust systems.
Q2: Why is a belt-drive configuration used for the motor?
A: The belt-drive method allows flexibility in adjusting the rotating speed of the impeller. It isolates the motor from the hot air and grease stream, protecting it from high temperatures and significantly extending its operational life.
Q3: How does the stainless steel structure improve durability?
A: Stainless steel provides excellent resistance to corrosion, rust, moisture, and extreme temperatures. This allows the centrifugal fan to operate reliably in humid kitchen environments and harsh industrial conditions.
Q4: Is the fan easy to clean and maintain?
A: Yes. The fan features a detachable structure where the power section is separated from the main casing. This design allows maintenance personnel to inspect, clean, and service the impeller and motor with minimal effort.
Q5: How does this fan control noise levels during operation?
A: The impeller and belt undergo strict dynamic and static balance correction before assembly. Additionally, the fan is equipped with high-performance spring shock absorbers to suppress vibrations and prevent high noise levels.
Q6: What applications are suitable for this centrifugal exhaust fan?
A: It is ideal for commercial kitchen fume extraction, warehouse ventilation, chemical factory exhaust, shopping mall HVAC systems, and dust collection systems requiring high static pressure.